            IFM Efector Self-Monitoring Temperature ...
 
                             
                             
                             
                             
                             
                             
                             
            Features:
| Product characteristics | |||||
|---|---|---|---|---|---|
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 | ||||
| Measuring range | 
 | ||||
| Process connection | threaded connection G 1/2 sealing cone | ||||
| Installation length EL [mm] | 30 | ||||
| Application | |||||
| Special feature | Gold-plated contacts | ||||
| Measuring element | 1 x Pt 1000 | ||||
| Reference element | 1 x NTC | ||||
| Media | liquids and gases | ||||
| Pressure rating [bar] | 160 | ||||
| Electrical data | |||||
| Operating voltage [V] | 18...32 DC; ("supply class 2" to cULus) | ||||
| Current consumption [mA] | 10; (24 V) | ||||
| Protection class | III | ||||
| Reverse polarity protection | yes | ||||
| Power-on delay time [s] | 6 | ||||
| Integrated watchdog | yes | ||||
| Inputs / outputs | |||||
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 | ||||
| Outputs | |||||
| Total number of outputs | 2 | ||||
| Output signal | analogue signal; IO-Link; calibration check status | ||||
| Electrical design | PNP/NPN | ||||
| Number of digital outputs | 1 | ||||
| Output function | normally closed; (diagnostic signal) | ||||
| Max. voltage drop switching output DC [V] | 2 | ||||
| Permanent current rating of switching output DC [mA] | 100 | ||||
| Diagnostic output | calibration check status and error diagnostics | ||||
| Number of analogue outputs | 1 | ||||
| Analogue current output [mA] | 4...20 | ||||
| Max. load [Ω] | (Ub - 15 V) x 50 | ||||
| Short-circuit protection | yes | ||||
| Type of short-circuit protection | pulsed | ||||
| Overload protection | yes | ||||
| Measuring/setting range | |||||
| Measuring range | 
 | ||||
| Note on measuring range | 
 | ||||
| Factory setting | -10...150 °C / 14...302 °F | ||||
| Calibration check limit [K] | 0.5...3 | ||||
| In steps of [K] | 0.05 | ||||
| Resolution | |||||
| Resolution of analogue output [K] | 0.05 | ||||
| Accuracy / deviations | |||||
| Precision analogue output [K] | ± 0,2 | ||||
| Precision IO-Link [K] | ± 0,2 | ||||
| Temperature coefficient analogue output [% of the span / 10 K] | < ± 0,02; (in case of deviation from the reference condition 25 ± 5 °C) | ||||
| Temperature coefficient IO-Link [% of the span / 10 K] | < ± 0,01; (in case of deviation from the reference condition 25 ± 5 °C) | ||||
| Response times | |||||
| Dynamic response T05 / T09 [s] | 1,5 / 4 | ||||
| Software / programming | |||||
| Parameter setting options | Display unit; scaling of the analogue output; calibration check limit; switching logic diagnostic output; simulation mode | ||||
| Interfaces | |||||
| Communication interface | IO-Link | ||||
| Transmission type | COM2 (38,4 kBaud) | ||||
| IO-Link revision | 1.1 | ||||
| SDCI standard | IEC 61131-9 CDV | ||||
| Profiles | Digital Measuring Sensor, Common Profile, Blob Transfer | ||||
| SIO mode | yes | ||||
| Required master port type | A | ||||
| Process data analogue | 1 | ||||
| Process data binary | 1 | ||||
| Min. process cycle time [ms] | 4.4 | ||||
| IO-Link resolution temperature [K] | 0.01 | ||||
| Supported DeviceIDs | 
 | ||||
| Operating conditions | |||||
| Ambient temperature [°C] | -25...70 | ||||
| Note on ambient temperature | 
 | ||||
| Storage temperature [°C] | -40...100 | ||||
| Protection | IP 68; IP 69K | ||||
| Tests / approvals | |||||
| EMC | 
 | ||||
| Shock resistance | 
 | ||||
| Vibration resistance | 
 | ||||
| MTTF [years] | 329 | ||||
| Note on approval | 
 | ||||
| UL approval | 
 | ||||
| Mechanical data | |||||
| Weight [g] | 365.1 | ||||
| Dimensions [mm] | Ø 50 / L = 124 | ||||
| Materials | stainless steel (1.4404 / 316L); PEI; FKM; PFA | ||||
| Materials (wetted parts) | stainless steel (1.4404 / 316L); PEEK | ||||
| Tightening torque [Nm] | 30...50 | ||||
| Process connection | threaded connection G 1/2 sealing cone | ||||
| Surface characteristics Ra/Rz of the wetted parts | Ra: < 0.8 | ||||
| Probe diameter [mm] | 6 | ||||
| Installation length EL [mm] | 30 | ||||
| Remarks | |||||
| Remarks | 
 | ||||
| Pack quantity | 1 pcs. | ||||
| Electrical connection | |||||
| Connection | Connector: 1 x M12; Contacts: gold-plated | ||||
| ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — TCC501-00 — 20.12.2021 — | |||||
To contact ifm efector about IFM Efector Self-Monitoring Temperature Sensor | TCC501 use Get a quote.
Features:
| Product characteristics | |||||
|---|---|---|---|---|---|
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 | ||||
| Measuring range | 
 | ||||
| Process connection | threaded connection G 1/2 sealing cone | ||||
| Installation length EL [mm] | 30 | ||||
| Application | |||||
| Special feature | Gold-plated contacts | ||||
| Measuring element | 1 x Pt 1000 | ||||
| Reference element | 1 x NTC | ||||
| Media | liquids and gases | ||||
| Pressure rating [bar] | 160 | ||||
| Electrical data | |||||
| Operating voltage [V] | 18...32 DC; ("supply class 2" to cULus) | ||||
| Current consumption [mA] | 10; (24 V) | ||||
| Protection class | III | ||||
| Reverse polarity protection | yes | ||||
| Power-on delay time [s] | 6 | ||||
| Integrated watchdog | yes | ||||
| Inputs / outputs | |||||
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 | ||||
| Outputs | |||||
| Total number of outputs | 2 | ||||
| Output signal | analogue signal; IO-Link; calibration check status | ||||
| Electrical design | PNP/NPN | ||||
| Number of digital outputs | 1 | ||||
| Output function | normally closed; (diagnostic signal) | ||||
| Max. voltage drop switching output DC [V] | 2 | ||||
| Permanent current rating of switching output DC [mA] | 100 | ||||
| Diagnostic output | calibration check status and error diagnostics | ||||
| Number of analogue outputs | 1 | ||||
| Analogue current output [mA] | 4...20 | ||||
| Max. load [Ω] | (Ub - 15 V) x 50 | ||||
| Short-circuit protection | yes | ||||
| Type of short-circuit protection | pulsed | ||||
| Overload protection | yes | ||||
| Measuring/setting range | |||||
| Measuring range | 
 | ||||
| Note on measuring range | 
 | ||||
| Factory setting | -10...150 °C / 14...302 °F | ||||
| Calibration check limit [K] | 0.5...3 | ||||
| In steps of [K] | 0.05 | ||||
| Resolution | |||||
| Resolution of analogue output [K] | 0.05 | ||||
| Accuracy / deviations | |||||
| Precision analogue output [K] | ± 0,2 | ||||
| Precision IO-Link [K] | ± 0,2 | ||||
| Temperature coefficient analogue output [% of the span / 10 K] | < ± 0,02; (in case of deviation from the reference condition 25 ± 5 °C) | ||||
| Temperature coefficient IO-Link [% of the span / 10 K] | < ± 0,01; (in case of deviation from the reference condition 25 ± 5 °C) | ||||
| Response times | |||||
| Dynamic response T05 / T09 [s] | 1,5 / 4 | ||||
| Software / programming | |||||
| Parameter setting options | Display unit; scaling of the analogue output; calibration check limit; switching logic diagnostic output; simulation mode | ||||
| Interfaces | |||||
| Communication interface | IO-Link | ||||
| Transmission type | COM2 (38,4 kBaud) | ||||
| IO-Link revision | 1.1 | ||||
| SDCI standard | IEC 61131-9 CDV | ||||
| Profiles | Digital Measuring Sensor, Common Profile, Blob Transfer | ||||
| SIO mode | yes | ||||
| Required master port type | A | ||||
| Process data analogue | 1 | ||||
| Process data binary | 1 | ||||
| Min. process cycle time [ms] | 4.4 | ||||
| IO-Link resolution temperature [K] | 0.01 | ||||
| Supported DeviceIDs | 
 | ||||
| Operating conditions | |||||
| Ambient temperature [°C] | -25...70 | ||||
| Note on ambient temperature | 
 | ||||
| Storage temperature [°C] | -40...100 | ||||
| Protection | IP 68; IP 69K | ||||
| Tests / approvals | |||||
| EMC | 
 | ||||
| Shock resistance | 
 | ||||
| Vibration resistance | 
 | ||||
| MTTF [years] | 329 | ||||
| Note on approval | 
 | ||||
| UL approval | 
 | ||||
| Mechanical data | |||||
| Weight [g] | 365.1 | ||||
| Dimensions [mm] | Ø 50 / L = 124 | ||||
| Materials | stainless steel (1.4404 / 316L); PEI; FKM; PFA | ||||
| Materials (wetted parts) | stainless steel (1.4404 / 316L); PEEK | ||||
| Tightening torque [Nm] | 30...50 | ||||
| Process connection | threaded connection G 1/2 sealing cone | ||||
| Surface characteristics Ra/Rz of the wetted parts | Ra: < 0.8 | ||||
| Probe diameter [mm] | 6 | ||||
| Installation length EL [mm] | 30 | ||||
| Remarks | |||||
| Remarks | 
 | ||||
| Pack quantity | 1 pcs. | ||||
| Electrical connection | |||||
| Connection | Connector: 1 x M12; Contacts: gold-plated | ||||
| ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — TCC501-00 — 20.12.2021 — | |||||
To contact ifm efector about IFM Efector Self-Monitoring Temperature Sensor | TCC501 use Get a quote.
 
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                         
                         
                         
                         
                         
                         
                         
                         
                         
                         
                        Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product
 
                         
     Reach valuable industrial buyers in minutes
                
                    Reach valuable industrial buyers in minutes
                
             Promote key products & content
                
                    Promote key products & content
                
             Drive cost effective & measurable sales
                
                    Drive cost effective & measurable sales