            IFM Efector Flow Sensor | SA5000
 
                             
                             
                             
            Features:
| Product characteristics | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | ||||||||
| Process connection | threaded connection M18 x 1,5 internal thread | ||||||||
| Application | |||||||||
| Special feature | Gold-plated contacts | ||||||||
| Media | water; glycol solutions; air; oils | ||||||||
| Note on media | 
 | ||||||||
| Medium temperature [°C] | -20...90 | ||||||||
| Pressure rating [bar] | 100 | ||||||||
| Pressure rating [Mpa] | 10 | ||||||||
| MAWP (for applications according to CRN) [bar] | 100 | ||||||||
| Electrical data | |||||||||
| Operating voltage [V] | 18...30 DC | ||||||||
| Current consumption [mA] | < 100 | ||||||||
| Protection class | III | ||||||||
| Reverse polarity protection | yes | ||||||||
| Power-on delay time [s] | 10 | ||||||||
| Inputs / outputs | |||||||||
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | ||||||||
| Outputs | |||||||||
| Total number of outputs | 2 | ||||||||
| Output signal | switching signal; analogue signal; frequency signal; IO-Link; (configurable) | ||||||||
| Electrical design | PNP/NPN | ||||||||
| Number of digital outputs | 2 | ||||||||
| Output function | normally open / normally closed; (parameterisable) | ||||||||
| Max. voltage drop switching output DC [V] | 2.5 | ||||||||
| Permanent current rating of switching output DC [mA] | 250 | ||||||||
| Number of analogue outputs | 1 | ||||||||
| Analogue current output [mA] | 4...20; (scalable) | ||||||||
| Max. load [Ω] | 350 | ||||||||
| Short-circuit protection | yes | ||||||||
| Type of short-circuit protection | pulsed | ||||||||
| Overload protection | yes | ||||||||
| Frequency of the output [Hz] | 0...1000 | ||||||||
| Measuring/setting range | |||||||||
| Probe length L [mm] | 45 | ||||||||
| Operating mode | relative; absolutely liquid; absolutely gaseous; (absolute: reference measurement recommended) | ||||||||
| Note on factory setting | 
 | ||||||||
| Temperature monitoring | |||||||||
| Measuring range [°C] | -20...90 | ||||||||
| Resolution [°C] | 0.2 | ||||||||
| Liquid media - absolute operating mode | |||||||||
| Setting range [m/s] | 0.04...3 | ||||||||
| Greatest sensitivity [m/s] | 0.04...3 | ||||||||
| Liquid media - relative operating mode | |||||||||
| Setting range [m/s] | 0.04...6 | ||||||||
| Greatest sensitivity [m/s] | 0.04...3 | ||||||||
| Gases - operating mode "absolute" | |||||||||
| Setting range [m/s] | 0...100 | ||||||||
| Greatest sensitivity [m/s] | 30...100 | ||||||||
| Gases - operating mode "relative" | |||||||||
| Setting range [m/s] | 0...200 | ||||||||
| Greatest sensitivity [m/s] | 30...100 | ||||||||
| Accuracy / deviations | |||||||||
| Temperature drift [cm/s x 1/K] | 0,003 m/s x 1/K (< 20 °C; > 70 °C) | ||||||||
| Temperature gradient [K/min] | 100 | ||||||||
| Absolute operating mode | |||||||||
| Repeatability | 0,05 m/s; (water; flow velocity: 0,05...3 m/s) | ||||||||
| Relative operating mode | |||||||||
| Accuracy | ± (7 % MW + 2 % MEW); (for relative mode in the range of maximum sensitivity under the following conditions:; water: 20...70 °C; inlet length: 1.5 m; DN25 (DIN 2448); mounting position according to instructions; Accuracy can differ for other media and mounting positions.) | ||||||||
| Repeatability | 0,05 m/s; (water; flow velocity: 0,05...3 m/s) | ||||||||
| Temperature monitoring | |||||||||
| Temperature drift | ± 0,005 K/°C | ||||||||
| Accuracy [K] | ± 0,3 / ± 1; (water; flow velocity: 0,3...3 m/s / air; flow velocity: > 10 m/s) | ||||||||
| Response times | |||||||||
| Response time [s] | 0.5; (T09; water; glycol: 0,8 s; air: 7 s; oil: 1,8 s; each T09) | ||||||||
| Temperature monitoring | |||||||||
| Dynamic response T05 / T09 [s] | 1,5 (T09); (water; flow velocity: 0,3...3 m/s) | ||||||||
| Software / programming | |||||||||
| Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; current/frequency output; medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value colour | ||||||||
| Interfaces | |||||||||
| Communication interface | IO-Link | ||||||||
| Transmission type | COM2 (38,4 kBaud) | ||||||||
| IO-Link revision | 1.1 | ||||||||
| SDCI standard | IEC 61131-9 | ||||||||
| Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | ||||||||
| SIO mode | yes | ||||||||
| Required master port type | A | ||||||||
| Process data analogue | 2 | ||||||||
| Process data binary | 2 | ||||||||
| Min. process cycle time [ms] | 3 | ||||||||
| Supported DeviceIDs | 
 | ||||||||
| Operating conditions | |||||||||
| Ambient temperature [°C] | -40...80 | ||||||||
| Storage temperature [°C] | -40...100 | ||||||||
| Protection | IP 65; IP 67 | ||||||||
| Tests / approvals | |||||||||
| EMC | 
 | ||||||||
| Shock resistance | 
 | ||||||||
| Vibration resistance | 
 | ||||||||
| UL approval | 
 | ||||||||
| Mechanical data | |||||||||
| Weight [g] | 314 | ||||||||
| Materials | stainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PBT-GF20; PBT-GF30 | ||||||||
| Materials (wetted parts) | stainless steel (1.4404 / 316L); Gasket: FKM | ||||||||
| Process connection | threaded connection M18 x 1,5 internal thread | ||||||||
| Displays / operating elements | |||||||||
| Display | 
 | ||||||||
| Remarks | |||||||||
| Remarks | 
 | ||||||||
| Pack quantity | 1 pcs. | ||||||||
| Electrical connection | |||||||||
| Connection | Connector: 1 x M12; Contacts: gold-plated | ||||||||
To contact ifm efector about IFM Efector Flow Sensor | SA5000 use Get a quote.
Features:
| Product characteristics | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | ||||||||
| Process connection | threaded connection M18 x 1,5 internal thread | ||||||||
| Application | |||||||||
| Special feature | Gold-plated contacts | ||||||||
| Media | water; glycol solutions; air; oils | ||||||||
| Note on media | 
 | ||||||||
| Medium temperature [°C] | -20...90 | ||||||||
| Pressure rating [bar] | 100 | ||||||||
| Pressure rating [Mpa] | 10 | ||||||||
| MAWP (for applications according to CRN) [bar] | 100 | ||||||||
| Electrical data | |||||||||
| Operating voltage [V] | 18...30 DC | ||||||||
| Current consumption [mA] | < 100 | ||||||||
| Protection class | III | ||||||||
| Reverse polarity protection | yes | ||||||||
| Power-on delay time [s] | 10 | ||||||||
| Inputs / outputs | |||||||||
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | ||||||||
| Outputs | |||||||||
| Total number of outputs | 2 | ||||||||
| Output signal | switching signal; analogue signal; frequency signal; IO-Link; (configurable) | ||||||||
| Electrical design | PNP/NPN | ||||||||
| Number of digital outputs | 2 | ||||||||
| Output function | normally open / normally closed; (parameterisable) | ||||||||
| Max. voltage drop switching output DC [V] | 2.5 | ||||||||
| Permanent current rating of switching output DC [mA] | 250 | ||||||||
| Number of analogue outputs | 1 | ||||||||
| Analogue current output [mA] | 4...20; (scalable) | ||||||||
| Max. load [Ω] | 350 | ||||||||
| Short-circuit protection | yes | ||||||||
| Type of short-circuit protection | pulsed | ||||||||
| Overload protection | yes | ||||||||
| Frequency of the output [Hz] | 0...1000 | ||||||||
| Measuring/setting range | |||||||||
| Probe length L [mm] | 45 | ||||||||
| Operating mode | relative; absolutely liquid; absolutely gaseous; (absolute: reference measurement recommended) | ||||||||
| Note on factory setting | 
 | ||||||||
| Temperature monitoring | |||||||||
| Measuring range [°C] | -20...90 | ||||||||
| Resolution [°C] | 0.2 | ||||||||
| Liquid media - absolute operating mode | |||||||||
| Setting range [m/s] | 0.04...3 | ||||||||
| Greatest sensitivity [m/s] | 0.04...3 | ||||||||
| Liquid media - relative operating mode | |||||||||
| Setting range [m/s] | 0.04...6 | ||||||||
| Greatest sensitivity [m/s] | 0.04...3 | ||||||||
| Gases - operating mode "absolute" | |||||||||
| Setting range [m/s] | 0...100 | ||||||||
| Greatest sensitivity [m/s] | 30...100 | ||||||||
| Gases - operating mode "relative" | |||||||||
| Setting range [m/s] | 0...200 | ||||||||
| Greatest sensitivity [m/s] | 30...100 | ||||||||
| Accuracy / deviations | |||||||||
| Temperature drift [cm/s x 1/K] | 0,003 m/s x 1/K (< 20 °C; > 70 °C) | ||||||||
| Temperature gradient [K/min] | 100 | ||||||||
| Absolute operating mode | |||||||||
| Repeatability | 0,05 m/s; (water; flow velocity: 0,05...3 m/s) | ||||||||
| Relative operating mode | |||||||||
| Accuracy | ± (7 % MW + 2 % MEW); (for relative mode in the range of maximum sensitivity under the following conditions:; water: 20...70 °C; inlet length: 1.5 m; DN25 (DIN 2448); mounting position according to instructions; Accuracy can differ for other media and mounting positions.) | ||||||||
| Repeatability | 0,05 m/s; (water; flow velocity: 0,05...3 m/s) | ||||||||
| Temperature monitoring | |||||||||
| Temperature drift | ± 0,005 K/°C | ||||||||
| Accuracy [K] | ± 0,3 / ± 1; (water; flow velocity: 0,3...3 m/s / air; flow velocity: > 10 m/s) | ||||||||
| Response times | |||||||||
| Response time [s] | 0.5; (T09; water; glycol: 0,8 s; air: 7 s; oil: 1,8 s; each T09) | ||||||||
| Temperature monitoring | |||||||||
| Dynamic response T05 / T09 [s] | 1,5 (T09); (water; flow velocity: 0,3...3 m/s) | ||||||||
| Software / programming | |||||||||
| Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; current/frequency output; medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value colour | ||||||||
| Interfaces | |||||||||
| Communication interface | IO-Link | ||||||||
| Transmission type | COM2 (38,4 kBaud) | ||||||||
| IO-Link revision | 1.1 | ||||||||
| SDCI standard | IEC 61131-9 | ||||||||
| Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | ||||||||
| SIO mode | yes | ||||||||
| Required master port type | A | ||||||||
| Process data analogue | 2 | ||||||||
| Process data binary | 2 | ||||||||
| Min. process cycle time [ms] | 3 | ||||||||
| Supported DeviceIDs | 
 | ||||||||
| Operating conditions | |||||||||
| Ambient temperature [°C] | -40...80 | ||||||||
| Storage temperature [°C] | -40...100 | ||||||||
| Protection | IP 65; IP 67 | ||||||||
| Tests / approvals | |||||||||
| EMC | 
 | ||||||||
| Shock resistance | 
 | ||||||||
| Vibration resistance | 
 | ||||||||
| UL approval | 
 | ||||||||
| Mechanical data | |||||||||
| Weight [g] | 314 | ||||||||
| Materials | stainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PBT-GF20; PBT-GF30 | ||||||||
| Materials (wetted parts) | stainless steel (1.4404 / 316L); Gasket: FKM | ||||||||
| Process connection | threaded connection M18 x 1,5 internal thread | ||||||||
| Displays / operating elements | |||||||||
| Display | 
 | ||||||||
| Remarks | |||||||||
| Remarks | 
 | ||||||||
| Pack quantity | 1 pcs. | ||||||||
| Electrical connection | |||||||||
| Connection | Connector: 1 x M12; Contacts: gold-plated | ||||||||
To contact ifm efector about IFM Efector Flow Sensor | SA5000 use Get a quote.
 
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                         
                         
                         
                         
                         
                         
                         
                         
                         
                         
                         
                         
                         
                         
                         
                         
                        Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product
 
                         
     Reach valuable industrial buyers in minutes
                
                    Reach valuable industrial buyers in minutes
                
             Promote key products & content
                
                    Promote key products & content
                
             Drive cost effective & measurable sales
                
                    Drive cost effective & measurable sales