            IFM Efector Pressure Sensor with Display ...
 
                             
            Features:
| Product characteristics | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Output signal | switching signal; IO-Link; (configurable) | ||||||||
| Measuring range | 
 | ||||||||
| Process connection | threaded connection G 1/4 internal thread | ||||||||
| Application | |||||||||
| Special feature | Gold-plated contacts | ||||||||
| Measuring element | metallic thin film cell | ||||||||
| Application | for industrial applications | ||||||||
| Media | liquids and gases | ||||||||
| Medium temperature [°C] | -25...80 | ||||||||
| Min. bursting pressure | 
 | ||||||||
| Pressure rating | 
 | ||||||||
| Vacuum resistance [mbar] | -1000 | ||||||||
| Type of pressure | relative pressure | ||||||||
| Electrical data | |||||||||
| Operating voltage [V] | 18...30 DC; (to SELV/PELV) | ||||||||
| Current consumption [mA] | < 35 | ||||||||
| Min. insulation resistance [MΩ] | 100; (500 V DC) | ||||||||
| Protection class | III | ||||||||
| Reverse polarity protection | yes | ||||||||
| Power-on delay time [s] | < 0.3 | ||||||||
| Integrated watchdog | yes | ||||||||
| Inputs / outputs | |||||||||
| Number of inputs and outputs | Number of digital outputs: 2 | ||||||||
| Outputs | |||||||||
| Total number of outputs | 2 | ||||||||
| Output signal | switching signal; IO-Link; (configurable) | ||||||||
| Electrical design | PNP/NPN | ||||||||
| Number of digital outputs | 2 | ||||||||
| Output function | normally open / normally closed; (parameterisable) | ||||||||
| Max. voltage drop switching output DC [V] | 2.5 | ||||||||
| Permanent current rating of switching output DC [mA] | 150; (200 (...60 °C) 250 (...40 °C)) | ||||||||
| Switching frequency DC [Hz] | < 170 | ||||||||
| Short-circuit protection | yes | ||||||||
| Type of short-circuit protection | pulsed | ||||||||
| Overload protection | yes | ||||||||
| Measuring/setting range | |||||||||
| Measuring range | 
 | ||||||||
| Factory setting / CMPT = 2 | |||||||||
| Set point SP | 
 | ||||||||
| Reset point rP | 
 | ||||||||
| Min. difference between SP and rP | 
 | ||||||||
| In steps of | 
 | ||||||||
| Status_B High Resolution / CMPT = 3 | |||||||||
| Set point SP | 
 | ||||||||
| Reset point rP | 
 | ||||||||
| Min. difference between SP and rP | 
 | ||||||||
| In steps of | 
 | ||||||||
| Accuracy / deviations | |||||||||
| Switch point accuracy [% of the span] | < ± 0,5 | ||||||||
| Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) | ||||||||
| Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) | ||||||||
| Hysteresis deviation [% of the span] | < ± 0,25 | ||||||||
| Long-term stability [% of the span] | < ± 0,05; (per 6 months) | ||||||||
| Temperature coefficient zero point [% of the span / 10 K] | 0,2; (-25...80 °C) | ||||||||
| Temperature coefficient span [% of the span / 10 K] | 0,2; (-25...80 °C) | ||||||||
| Response times | |||||||||
| Response time [ms] | < 3 | ||||||||
| Delay time programmable dS, dr [s] | 0...50 | ||||||||
| Software / programming | |||||||||
| Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping; Display unit | ||||||||
| Interfaces | |||||||||
| Communication interface | IO-Link | ||||||||
| Transmission type | COM2 (38,4 kBaud) | ||||||||
| IO-Link revision | 1.1 | ||||||||
| SDCI standard | IEC 61131-9 | ||||||||
| SIO mode | yes | ||||||||
| Required master port type | A; (when pin 2 not connected: B) | ||||||||
| Process data analogue | 1 | ||||||||
| Process data binary | 2 | ||||||||
| Supported DeviceIDs | 
 | ||||||||
| Note | 
 | ||||||||
| Factory setting / CMPT = 2 | |||||||||
| Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | ||||||||
| Min. process cycle time [ms] | 2.3 | ||||||||
| IO-Link resolution pressure [bar] | 1 | ||||||||
| IO-Link resolution pressure [MPa] | 0.1 | ||||||||
| IO-Link process data (cyclical) | 
 | ||||||||
| IO-Link functions (acyclical) | application specific tag | ||||||||
| Status_B High Resolution / CMPT = 3 | |||||||||
| Profiles | Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) | ||||||||
| Min. process cycle time [ms] | 3 | ||||||||
| IO-Link resolution pressure [bar] | 0.1 | ||||||||
| IO-Link resolution pressure [MPa] | 0.02 | ||||||||
| IO-Link process data (cyclical) | 
 | ||||||||
| IO-Link functions (acyclical) | application specific tag | ||||||||
| Operating conditions | |||||||||
| Ambient temperature [°C] | -25...80 | ||||||||
| Storage temperature [°C] | -40...100 | ||||||||
| Protection | IP 65; IP 67 | ||||||||
| Tests / approvals | |||||||||
| EMC | 
 | ||||||||
| Shock resistance | 
 | ||||||||
| Vibration resistance | 
 | ||||||||
| UL approval | 
 | ||||||||
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request | ||||||||
| Mechanical data | |||||||||
| Weight [g] | 239.2 | ||||||||
| Materials | 1.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC | ||||||||
| Materials (wetted parts) | 1.4542 (17-4 PH / 630) | ||||||||
| Min. pressure cycles | 100 million | ||||||||
| Tightening torque [Nm] | 25...35; (recommended tightening torque; depends on lubrication, seal and pressure rating) | ||||||||
| Process connection | threaded connection G 1/4 internal thread | ||||||||
| Restrictor element integrated | no (can be retrofitted) | ||||||||
| Displays / operating elements | |||||||||
| Display | 
 | ||||||||
| Remarks | |||||||||
| Pack quantity | 1 pcs. | ||||||||
| Electrical connection | |||||||||
| Connection | Connector: 1 x M12; Contacts: gold-plated | ||||||||
To contact ifm efector about IFM Efector Pressure Sensor with Display | PN7071 use Get a quote.
Features:
| Product characteristics | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Output signal | switching signal; IO-Link; (configurable) | ||||||||
| Measuring range | 
 | ||||||||
| Process connection | threaded connection G 1/4 internal thread | ||||||||
| Application | |||||||||
| Special feature | Gold-plated contacts | ||||||||
| Measuring element | metallic thin film cell | ||||||||
| Application | for industrial applications | ||||||||
| Media | liquids and gases | ||||||||
| Medium temperature [°C] | -25...80 | ||||||||
| Min. bursting pressure | 
 | ||||||||
| Pressure rating | 
 | ||||||||
| Vacuum resistance [mbar] | -1000 | ||||||||
| Type of pressure | relative pressure | ||||||||
| Electrical data | |||||||||
| Operating voltage [V] | 18...30 DC; (to SELV/PELV) | ||||||||
| Current consumption [mA] | < 35 | ||||||||
| Min. insulation resistance [MΩ] | 100; (500 V DC) | ||||||||
| Protection class | III | ||||||||
| Reverse polarity protection | yes | ||||||||
| Power-on delay time [s] | < 0.3 | ||||||||
| Integrated watchdog | yes | ||||||||
| Inputs / outputs | |||||||||
| Number of inputs and outputs | Number of digital outputs: 2 | ||||||||
| Outputs | |||||||||
| Total number of outputs | 2 | ||||||||
| Output signal | switching signal; IO-Link; (configurable) | ||||||||
| Electrical design | PNP/NPN | ||||||||
| Number of digital outputs | 2 | ||||||||
| Output function | normally open / normally closed; (parameterisable) | ||||||||
| Max. voltage drop switching output DC [V] | 2.5 | ||||||||
| Permanent current rating of switching output DC [mA] | 150; (200 (...60 °C) 250 (...40 °C)) | ||||||||
| Switching frequency DC [Hz] | < 170 | ||||||||
| Short-circuit protection | yes | ||||||||
| Type of short-circuit protection | pulsed | ||||||||
| Overload protection | yes | ||||||||
| Measuring/setting range | |||||||||
| Measuring range | 
 | ||||||||
| Factory setting / CMPT = 2 | |||||||||
| Set point SP | 
 | ||||||||
| Reset point rP | 
 | ||||||||
| Min. difference between SP and rP | 
 | ||||||||
| In steps of | 
 | ||||||||
| Status_B High Resolution / CMPT = 3 | |||||||||
| Set point SP | 
 | ||||||||
| Reset point rP | 
 | ||||||||
| Min. difference between SP and rP | 
 | ||||||||
| In steps of | 
 | ||||||||
| Accuracy / deviations | |||||||||
| Switch point accuracy [% of the span] | < ± 0,5 | ||||||||
| Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) | ||||||||
| Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) | ||||||||
| Hysteresis deviation [% of the span] | < ± 0,25 | ||||||||
| Long-term stability [% of the span] | < ± 0,05; (per 6 months) | ||||||||
| Temperature coefficient zero point [% of the span / 10 K] | 0,2; (-25...80 °C) | ||||||||
| Temperature coefficient span [% of the span / 10 K] | 0,2; (-25...80 °C) | ||||||||
| Response times | |||||||||
| Response time [ms] | < 3 | ||||||||
| Delay time programmable dS, dr [s] | 0...50 | ||||||||
| Software / programming | |||||||||
| Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping; Display unit | ||||||||
| Interfaces | |||||||||
| Communication interface | IO-Link | ||||||||
| Transmission type | COM2 (38,4 kBaud) | ||||||||
| IO-Link revision | 1.1 | ||||||||
| SDCI standard | IEC 61131-9 | ||||||||
| SIO mode | yes | ||||||||
| Required master port type | A; (when pin 2 not connected: B) | ||||||||
| Process data analogue | 1 | ||||||||
| Process data binary | 2 | ||||||||
| Supported DeviceIDs | 
 | ||||||||
| Note | 
 | ||||||||
| Factory setting / CMPT = 2 | |||||||||
| Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | ||||||||
| Min. process cycle time [ms] | 2.3 | ||||||||
| IO-Link resolution pressure [bar] | 1 | ||||||||
| IO-Link resolution pressure [MPa] | 0.1 | ||||||||
| IO-Link process data (cyclical) | 
 | ||||||||
| IO-Link functions (acyclical) | application specific tag | ||||||||
| Status_B High Resolution / CMPT = 3 | |||||||||
| Profiles | Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) | ||||||||
| Min. process cycle time [ms] | 3 | ||||||||
| IO-Link resolution pressure [bar] | 0.1 | ||||||||
| IO-Link resolution pressure [MPa] | 0.02 | ||||||||
| IO-Link process data (cyclical) | 
 | ||||||||
| IO-Link functions (acyclical) | application specific tag | ||||||||
| Operating conditions | |||||||||
| Ambient temperature [°C] | -25...80 | ||||||||
| Storage temperature [°C] | -40...100 | ||||||||
| Protection | IP 65; IP 67 | ||||||||
| Tests / approvals | |||||||||
| EMC | 
 | ||||||||
| Shock resistance | 
 | ||||||||
| Vibration resistance | 
 | ||||||||
| UL approval | 
 | ||||||||
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request | ||||||||
| Mechanical data | |||||||||
| Weight [g] | 239.2 | ||||||||
| Materials | 1.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC | ||||||||
| Materials (wetted parts) | 1.4542 (17-4 PH / 630) | ||||||||
| Min. pressure cycles | 100 million | ||||||||
| Tightening torque [Nm] | 25...35; (recommended tightening torque; depends on lubrication, seal and pressure rating) | ||||||||
| Process connection | threaded connection G 1/4 internal thread | ||||||||
| Restrictor element integrated | no (can be retrofitted) | ||||||||
| Displays / operating elements | |||||||||
| Display | 
 | ||||||||
| Remarks | |||||||||
| Pack quantity | 1 pcs. | ||||||||
| Electrical connection | |||||||||
| Connection | Connector: 1 x M12; Contacts: gold-plated | ||||||||
To contact ifm efector about IFM Efector Pressure Sensor with Display | PN7071 use Get a quote.
 
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                         
                         
                         
                         
                         
                         
                         
                         
                         
                         
                         
                         
                         
                         
                         
                         
                         
                         
                        Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product
 
                         
     Reach valuable industrial buyers in minutes
                
                    Reach valuable industrial buyers in minutes
                
             Promote key products & content
                
                    Promote key products & content
                
             Drive cost effective & measurable sales
                
                    Drive cost effective & measurable sales