Features:
| Product characteristics | |||||||
|---|---|---|---|---|---|---|---|
| Electrical design | PNP | ||||||
| Output function | normally open / normally closed; (parameterisable) | ||||||
| Sensing range [mm] | 8 | ||||||
| Dimensions [mm] | M18 x 1 / L = 68 | ||||||
| Application | |||||||
| Special feature | Gold-plated contacts | ||||||
| Application | evaluation of rotating and linear movements with regard to underspeed; blocking | ||||||
| Electrical data | |||||||
| Nominal voltage DC [V] | 10...36 | ||||||
| Current consumption [mA] | < 15 | ||||||
| Protection class | II | ||||||
| Reverse polarity protection | yes | ||||||
| Outputs | |||||||
| Electrical design | PNP | ||||||
| Output function | normally open / normally closed; (parameterisable) | ||||||
| Max. voltage drop switching output DC [V] | 2.5 | ||||||
| Permanent current rating of switching output DC [mA] | 150; (when used outside the hazardous area: 250; Pulse output: 15) | ||||||
| Short-circuit protection | yes | ||||||
| Type of short-circuit protection | pulsed | ||||||
| Overload protection | yes | ||||||
| Detection zone | |||||||
| Sensing range [mm] | 8 | ||||||
| Sensing range adjustable | no | ||||||
| Operating distance [mm] | 0...6 | ||||||
| Measuring/setting range | |||||||
| Setting range [Imp/min] | 3...6000 | ||||||
| Accuracy / deviations | |||||||
| Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.4 / copper: 0.3 | ||||||
| Hysteresis [% of Sr] | 10 | ||||||
| Response times | |||||||
| Start-up delay [s] | 0...15 | ||||||
| Max. damping frequency [Imp/min] | 18000 | ||||||
| Software / programming | |||||||
| Adjustment of the switch point | Teach function | ||||||
| Operating conditions | |||||||
| Ambient temperature [°C] | -20...50 | ||||||
| Note on ambient temperature |
|
||||||
| Storage temperature [°C] | -25...60 | ||||||
| Protection | IP 67 | ||||||
| Tests / approvals | |||||||
| ATEX marking | II 3D Ex tc IIIC T80°C Dc IP67 U | ||||||
| Note on ATEX marking |
|
||||||
| EMC |
|
||||||
| Mechanical data | |||||||
| Weight [g] | 177 | ||||||
| Mounting | non-flush mountable | ||||||
| Dimensions [mm] | M18 x 1 / L = 68 | ||||||
| Thread designation | M18 x 1 | ||||||
| Materials | stainless steel (1.4571/316Ti ); PBT; TPE-U | ||||||
| Displays / operating elements | |||||||
| Display |
|
||||||
| Accessories | |||||||
| Items supplied |
|
||||||
| Electrical connection - plug | |||||||
| Connection | Connector: 1 x M12; Contacts: gold-plated | ||||||
To contact ifm efector about IFM Efector Compact Speed Sensor for Hazardous Areas | DI602A use Get a quote.
Features:
| Product characteristics | |||||||
|---|---|---|---|---|---|---|---|
| Electrical design | PNP | ||||||
| Output function | normally open / normally closed; (parameterisable) | ||||||
| Sensing range [mm] | 8 | ||||||
| Dimensions [mm] | M18 x 1 / L = 68 | ||||||
| Application | |||||||
| Special feature | Gold-plated contacts | ||||||
| Application | evaluation of rotating and linear movements with regard to underspeed; blocking | ||||||
| Electrical data | |||||||
| Nominal voltage DC [V] | 10...36 | ||||||
| Current consumption [mA] | < 15 | ||||||
| Protection class | II | ||||||
| Reverse polarity protection | yes | ||||||
| Outputs | |||||||
| Electrical design | PNP | ||||||
| Output function | normally open / normally closed; (parameterisable) | ||||||
| Max. voltage drop switching output DC [V] | 2.5 | ||||||
| Permanent current rating of switching output DC [mA] | 150; (when used outside the hazardous area: 250; Pulse output: 15) | ||||||
| Short-circuit protection | yes | ||||||
| Type of short-circuit protection | pulsed | ||||||
| Overload protection | yes | ||||||
| Detection zone | |||||||
| Sensing range [mm] | 8 | ||||||
| Sensing range adjustable | no | ||||||
| Operating distance [mm] | 0...6 | ||||||
| Measuring/setting range | |||||||
| Setting range [Imp/min] | 3...6000 | ||||||
| Accuracy / deviations | |||||||
| Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.4 / copper: 0.3 | ||||||
| Hysteresis [% of Sr] | 10 | ||||||
| Response times | |||||||
| Start-up delay [s] | 0...15 | ||||||
| Max. damping frequency [Imp/min] | 18000 | ||||||
| Software / programming | |||||||
| Adjustment of the switch point | Teach function | ||||||
| Operating conditions | |||||||
| Ambient temperature [°C] | -20...50 | ||||||
| Note on ambient temperature |
|
||||||
| Storage temperature [°C] | -25...60 | ||||||
| Protection | IP 67 | ||||||
| Tests / approvals | |||||||
| ATEX marking | II 3D Ex tc IIIC T80°C Dc IP67 U | ||||||
| Note on ATEX marking |
|
||||||
| EMC |
|
||||||
| Mechanical data | |||||||
| Weight [g] | 177 | ||||||
| Mounting | non-flush mountable | ||||||
| Dimensions [mm] | M18 x 1 / L = 68 | ||||||
| Thread designation | M18 x 1 | ||||||
| Materials | stainless steel (1.4571/316Ti ); PBT; TPE-U | ||||||
| Displays / operating elements | |||||||
| Display |
|
||||||
| Accessories | |||||||
| Items supplied |
|
||||||
| Electrical connection - plug | |||||||
| Connection | Connector: 1 x M12; Contacts: gold-plated | ||||||
To contact ifm efector about IFM Efector Compact Speed Sensor for Hazardous Areas | DI602A use Get a quote.