SaniForce High Sanitation Diaphragm Pump ...
FEATURES
SaniForce 1590 3A High Sanitation Diaphragm Pump:
Designed to detect leaks!
EPDM Overmolded Diaphragms:
SPECIFICATIONS
| SaniForce 1590 HS and 1590 3A Diaphragm Pumps | |
| Maximum fluid working pressure |
8 bar, 0.8 MPa
|
| Air pressure operating range |
1.4–8 bar, 0.14–0.8 MPa
|
| Maximum air consumption |
3.5 m³/minute
|
| Air consumption at 70 psi, 60 gpm |
1.4 m³/minute
|
| Maximum free-flow delivery |
378 lpm
|
| Maximum pump speed |
200 cpm
|
| Gallons/liters per cycle* |
2.0 l
|
| Maximum suction lift (varies widely based on ball/seat selection and wear, operating speed, material properties, and other variables) |
8.5 m wet, 4.6 m dry
|
| Maximum size pumpable solids |
15.9 mm
|
| Air inlet size |
0.5 in npt(f)
|
| Noise Data** | |
| Maximum Noise Level at 100 psi (7 bar, 0.7 MPa), full flow |
90 dB(A)
|
| Sound power level |
103 dB(A)
|
| Noise level at 70 psi (4.8 bar, 0.48 MPa), 50 cpm |
85dB(A)
|
| Maximum fluid operating temperature is based on the following maximum diaphragm, ball, and o-ring temperature ratings | |
| PTFE |
104°C
|
| Santoprene® |
82°C
|
| 3A Approved EPDM |
135°C
|
| Wetted Parts*** | |
| All fluid contact materials are FDA-compliant and meet the United States Code of Federal Regulations (CFR) Title 21, Section 177. | |
| Wetted materials on all models |
316 stainless steel, 3A Approved EPDM, PTFE
|
| Wetted materials depending on model |
3A Approved EPDM, PTFE, Santoprene
|
| CAUTION: Santoprene may be used only with non-fatty, non-oily foods or alcohols up to 15% | |
| Non-wetted external parts |
300 series stainless steel, polyester (labels), LDPE foam (gasket)
|
| Weight | |
| All Models |
44 kg
|
| Santoprene® is a registered trademark of the Monsanto Co. Loctite® is a registered trademark of the Loctite Corporation. * Displacement per cycle may vary based on suction condition, discharge head, air pressure, and fluid type. ** Noise levels measured with the pump mounted to a solid surface. Sound power measured per ISO Standard 9614–1. *** The pump user must verify that the construction materials meet their specific application requirements. | |
To contact Graco Australia about SaniForce High Sanitation Diaphragm Pump | 1590 3A use Get a quote.
FEATURES
SaniForce 1590 3A High Sanitation Diaphragm Pump:
Designed to detect leaks!
EPDM Overmolded Diaphragms:
SPECIFICATIONS
| SaniForce 1590 HS and 1590 3A Diaphragm Pumps | |
| Maximum fluid working pressure |
8 bar, 0.8 MPa
|
| Air pressure operating range |
1.4–8 bar, 0.14–0.8 MPa
|
| Maximum air consumption |
3.5 m³/minute
|
| Air consumption at 70 psi, 60 gpm |
1.4 m³/minute
|
| Maximum free-flow delivery |
378 lpm
|
| Maximum pump speed |
200 cpm
|
| Gallons/liters per cycle* |
2.0 l
|
| Maximum suction lift (varies widely based on ball/seat selection and wear, operating speed, material properties, and other variables) |
8.5 m wet, 4.6 m dry
|
| Maximum size pumpable solids |
15.9 mm
|
| Air inlet size |
0.5 in npt(f)
|
| Noise Data** | |
| Maximum Noise Level at 100 psi (7 bar, 0.7 MPa), full flow |
90 dB(A)
|
| Sound power level |
103 dB(A)
|
| Noise level at 70 psi (4.8 bar, 0.48 MPa), 50 cpm |
85dB(A)
|
| Maximum fluid operating temperature is based on the following maximum diaphragm, ball, and o-ring temperature ratings | |
| PTFE |
104°C
|
| Santoprene® |
82°C
|
| 3A Approved EPDM |
135°C
|
| Wetted Parts*** | |
| All fluid contact materials are FDA-compliant and meet the United States Code of Federal Regulations (CFR) Title 21, Section 177. | |
| Wetted materials on all models |
316 stainless steel, 3A Approved EPDM, PTFE
|
| Wetted materials depending on model |
3A Approved EPDM, PTFE, Santoprene
|
| CAUTION: Santoprene may be used only with non-fatty, non-oily foods or alcohols up to 15% | |
| Non-wetted external parts |
300 series stainless steel, polyester (labels), LDPE foam (gasket)
|
| Weight | |
| All Models |
44 kg
|
| Santoprene® is a registered trademark of the Monsanto Co. Loctite® is a registered trademark of the Loctite Corporation. * Displacement per cycle may vary based on suction condition, discharge head, air pressure, and fluid type. ** Noise levels measured with the pump mounted to a solid surface. Sound power measured per ISO Standard 9614–1. *** The pump user must verify that the construction materials meet their specific application requirements. | |
To contact Graco Australia about SaniForce High Sanitation Diaphragm Pump | 1590 3A use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product