4-Channel Source Measurement Unit
The NI PXIe-4141 is a high-channel-count, high-speed, precision source measure unit (SMU) with four identical SMU channels per PXI Express slot.
Each SMU offers 4-quadrant operation to source or sink ±10 V at ±100 mA. With integrated remote (4-wire) sensing and current measurement sensitivity of 10 pA, the NI PXIe-4141 is ideal for precision measurements including accurate characterisation of idle currents.
Specifications:
| General | |
| Product Family | Power Supplies |
| Form Factor | PXI Platform |
| PXI Bus Type | PXI Express |
| Part Number | 781743-01 |
| Operating System/Target | Real-Time , Windows |
| LabVIEW RT Support | Yes |
| Triggering | SoftwareTrigger , ExternalTrigger , InternalTrigger |
| External Clocking | No |
| I/O Connector | 25-pin D-Sub |
| Product Name | NI PXIe-4141 |
| Analog Output | |
| Channels | 4 |
| Resolution | 18 bits |
| Timing | Hardware |
| Update Rate | 100 kS/s |
| Current Drive Single | 100 mA |
| Current Drive All | 400 mA |
| Output Impedance | -100 kOhm , 100 kOhm |
| Max Voltage | -10 V , 10 V |
| Maximum Voltage Range Accuracy | 600 µV |
| Maximum Voltage Range Sensitivity | 10 µV |
| Minimum Voltage Range | -10 V , 10 V |
| Minimum Voltage Range Accuracy | 600 µV |
| Min Voltage Range Sensitivity | 10 µV |
| Max Current Range | -100 mA , 100 mA |
| Maximum Current Range Accuracy | 15 µA |
| Maximum Current Range Sensitivity | 100 nA |
| Minimum Current Range | -10 µA , 10 µA |
| Minimum Current Range Accuracy | 1.5 nA |
| Min Current Range Sensitivity | 10 pA |
| Output Quadrants | Quadrant III , Quadrant II , Quadrant IV , Quadrant I |
| Max Quadrants Per Channel | 4 |
To find out more about the NI PXIe, kindly log on to http://sine.ni.com/ds/app/doc/p/id/ds-359/lang/en
To contact National Instruments Australia about 4-Channel Source Measurement Unit use Get a quote.
The NI PXIe-4141 is a high-channel-count, high-speed, precision source measure unit (SMU) with four identical SMU channels per PXI Express slot.
Each SMU offers 4-quadrant operation to source or sink ±10 V at ±100 mA. With integrated remote (4-wire) sensing and current measurement sensitivity of 10 pA, the NI PXIe-4141 is ideal for precision measurements including accurate characterisation of idle currents.
Specifications:
| General | |
| Product Family | Power Supplies |
| Form Factor | PXI Platform |
| PXI Bus Type | PXI Express |
| Part Number | 781743-01 |
| Operating System/Target | Real-Time , Windows |
| LabVIEW RT Support | Yes |
| Triggering | SoftwareTrigger , ExternalTrigger , InternalTrigger |
| External Clocking | No |
| I/O Connector | 25-pin D-Sub |
| Product Name | NI PXIe-4141 |
| Analog Output | |
| Channels | 4 |
| Resolution | 18 bits |
| Timing | Hardware |
| Update Rate | 100 kS/s |
| Current Drive Single | 100 mA |
| Current Drive All | 400 mA |
| Output Impedance | -100 kOhm , 100 kOhm |
| Max Voltage | -10 V , 10 V |
| Maximum Voltage Range Accuracy | 600 µV |
| Maximum Voltage Range Sensitivity | 10 µV |
| Minimum Voltage Range | -10 V , 10 V |
| Minimum Voltage Range Accuracy | 600 µV |
| Min Voltage Range Sensitivity | 10 µV |
| Max Current Range | -100 mA , 100 mA |
| Maximum Current Range Accuracy | 15 µA |
| Maximum Current Range Sensitivity | 100 nA |
| Minimum Current Range | -10 µA , 10 µA |
| Minimum Current Range Accuracy | 1.5 nA |
| Min Current Range Sensitivity | 10 pA |
| Output Quadrants | Quadrant III , Quadrant II , Quadrant IV , Quadrant I |
| Max Quadrants Per Channel | 4 |
To find out more about the NI PXIe, kindly log on to http://sine.ni.com/ds/app/doc/p/id/ds-359/lang/en
To contact National Instruments Australia about 4-Channel Source Measurement Unit use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.