            Noshok Noshok Sanitary Clamp Pressure ...
 
                             
            Product Features:
Applications:
| SPECIFICATIONS | |
| Output signals | 4 mA to 20 mA 2-wire, 0 Vdc to 5 Vdc 3-wire, 1 Vdc to 5 Vdc 3-wire, 1 Vdc to 6 Vdc 3-wire, 0 Vdc to 10 Vdc, 3-wire, 1 Vdc to 11 Vdc 3-wire | 
| Pressure ranges | Vacuum through 0 psig to 400 psig | 
| Accuracy | ±0.25% full scale (BFSL); Optional ±0.125% full scale (BFSL); (Includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors) | 
| Stability | ±0.2% full scale for 1 year, non-accumulating | 
| Adjustment | ±10% full scale for zero and span | 
| Response time | < 10 ms | 
| Service life | > 100,000,000 load cycles | 
| Temperature ranges | Compensated 32 °F to 175 °F (0 °C to 80 °C) Effect ±0.01%/°F for zero and span Media -40 °F to 300 °F (-40 °C to 150 °C) Ambient -40 °F to 176 °F (-40 °C to 80 °C) Storage -40 °F to 212 °F (-40 °C to 100 °C) | 
| Power requirement* | 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire, 0 Vdc to 5 Vdc, 3-wire, 1 Vdc to 5 Vdc, 3-wire, 1 Vdc to 6 Vdc, 3-wire) 14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire, Vdc to 11 Vdc, 3-wire) | 
| Load limitations | = (VPower -10)/0.020 Amp for 4 mA to 20 mA output = 5,000 O for 1 Vdc to 5 Vdc output = 10,000 O for 0 Vdc to 10 Vdc output = 4,500 O for 0.5 Vdc to 4.5 Vdc output | 
| Proof pressure | 3 times full scale for 0 psig to 2 psig through 0 psig to 200 psig 1.75 times full scale for 0 psig to 300 psig through 0 psig to 400 psig | 
| Burst pressure | 3.8 times full scale for 0 psig to 2 psig through 0 psig to 200 psig 4 times full scale for 0 psig to 300 psig through 0 psig to 400 psig | 
| Measuring element | 316 stainless steel | 
| Connection | 316 stainless steel | 
| Housing material | 316 stainless steel | 
| Environmental rating | IP65 | 
| Electromagnetic rating | CE compliant to EMC norm EN 61326:1997/A1:1998 RFI, EMI and ESD protection | 
| Electrical protection | Reverse polarity, overvoltage and short circuit protection | 
| Shock | 1,000 g’s according to IEC 60068-2-27 | 
| Vibration | 15 g’s according to IEC 60068-2-6 | 
| Weight | Approximately 1.1 lb. | 
To contact AMS Instrumentation & Calibration about Noshok Noshok Sanitary Clamp Pressure Transmitters | 11 Series ASME-BPE use Get a quote.
Product Features:
Applications:
| SPECIFICATIONS | |
| Output signals | 4 mA to 20 mA 2-wire, 0 Vdc to 5 Vdc 3-wire, 1 Vdc to 5 Vdc 3-wire, 1 Vdc to 6 Vdc 3-wire, 0 Vdc to 10 Vdc, 3-wire, 1 Vdc to 11 Vdc 3-wire | 
| Pressure ranges | Vacuum through 0 psig to 400 psig | 
| Accuracy | ±0.25% full scale (BFSL); Optional ±0.125% full scale (BFSL); (Includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors) | 
| Stability | ±0.2% full scale for 1 year, non-accumulating | 
| Adjustment | ±10% full scale for zero and span | 
| Response time | < 10 ms | 
| Service life | > 100,000,000 load cycles | 
| Temperature ranges | Compensated 32 °F to 175 °F (0 °C to 80 °C) Effect ±0.01%/°F for zero and span Media -40 °F to 300 °F (-40 °C to 150 °C) Ambient -40 °F to 176 °F (-40 °C to 80 °C) Storage -40 °F to 212 °F (-40 °C to 100 °C) | 
| Power requirement* | 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire, 0 Vdc to 5 Vdc, 3-wire, 1 Vdc to 5 Vdc, 3-wire, 1 Vdc to 6 Vdc, 3-wire) 14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire, Vdc to 11 Vdc, 3-wire) | 
| Load limitations | = (VPower -10)/0.020 Amp for 4 mA to 20 mA output = 5,000 O for 1 Vdc to 5 Vdc output = 10,000 O for 0 Vdc to 10 Vdc output = 4,500 O for 0.5 Vdc to 4.5 Vdc output | 
| Proof pressure | 3 times full scale for 0 psig to 2 psig through 0 psig to 200 psig 1.75 times full scale for 0 psig to 300 psig through 0 psig to 400 psig | 
| Burst pressure | 3.8 times full scale for 0 psig to 2 psig through 0 psig to 200 psig 4 times full scale for 0 psig to 300 psig through 0 psig to 400 psig | 
| Measuring element | 316 stainless steel | 
| Connection | 316 stainless steel | 
| Housing material | 316 stainless steel | 
| Environmental rating | IP65 | 
| Electromagnetic rating | CE compliant to EMC norm EN 61326:1997/A1:1998 RFI, EMI and ESD protection | 
| Electrical protection | Reverse polarity, overvoltage and short circuit protection | 
| Shock | 1,000 g’s according to IEC 60068-2-27 | 
| Vibration | 15 g’s according to IEC 60068-2-6 | 
| Weight | Approximately 1.1 lb. | 
To contact AMS Instrumentation & Calibration about Noshok Noshok Sanitary Clamp Pressure Transmitters | 11 Series ASME-BPE use Get a quote.
 
                     
                     
                    -280x280-state_7.jpg) 
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                         
                         
                         
                         
                         
                         
                         
                         
                         
                         
                         
                         
                         
                         
                         
                         
                         
                        Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product
 
                         
     Reach valuable industrial buyers in minutes
                
                    Reach valuable industrial buyers in minutes
                
             Promote key products & content
                
                    Promote key products & content
                
             Drive cost effective & measurable sales
                
                    Drive cost effective & measurable sales