Anton Paar Hygienic Mass Flow Meter | ...
Features:
Our Type S L-Cor 6000 Coriolis hygienic mass flow meters, built with titanium single straight tubes, are designed for hygienic applications. They’re your solution for highly accurate measurements of gases and shear-sensitive or viscous liquids, slurries, aggressive media, or media with a low flow velocity.
If fast and positive process fluid replacement or draining of the pipeline is what you need, then this is the mass flow meter for you.
| L-Cor 6000 | |
| Measuring range | 36 kg/h to 61 200 kg/h |
| Flow accuracy | ± 0.15 % ± ZS* |
| Flow repeatability | ± 0.075 % ± ½ ZS* |
| Density range | 500 kg/m3 to 1,000 kg/m3 or 700 kg/m3 to 1,300 kg/m3 or 1000 kg/m3 to 1,500 kg/m3 |
| Density accuracy | ± 2 kg/m3 |
| Nominal diameter | 1/2” to 3” |
| Ambient temperature | - 40 °C to +55 °C |
| Process temperature | - 40 °C to +130 °C |
| Process pressure absolute | According to flange specification |
| Process connection | ASME B16.5 Class 150 Tri-clamp ISO 2852 |
| Wetted parts | Titanium alloy |
| Approvals for potentially explosive atmospheres | ATEX, IECEx, CSA (C-US), NEPSI (CCC) |
| Outputs | 2x analog, 2x pulse (frequency), 1x status output |
| Inputs | 1x status input |
| Digital communication | Bell 202, Modbus RTU (RS-485), Profibus PA, Fieldbus |
| Transmitter version | Integrated, separately mounted, mounted in control cabinet |
| Certifications | EHEDG |
*Accuracy valid at reference conditions. ZS = Zero stability error = (Zero stability)/(Flowrate at the moment) x100%
To contact Anton Paar Australia about Anton Paar Hygienic Mass Flow Meter | L-Cor 6000 use Get a quote.
Features:
Our Type S L-Cor 6000 Coriolis hygienic mass flow meters, built with titanium single straight tubes, are designed for hygienic applications. They’re your solution for highly accurate measurements of gases and shear-sensitive or viscous liquids, slurries, aggressive media, or media with a low flow velocity.
If fast and positive process fluid replacement or draining of the pipeline is what you need, then this is the mass flow meter for you.
| L-Cor 6000 | |
| Measuring range | 36 kg/h to 61 200 kg/h |
| Flow accuracy | ± 0.15 % ± ZS* |
| Flow repeatability | ± 0.075 % ± ½ ZS* |
| Density range | 500 kg/m3 to 1,000 kg/m3 or 700 kg/m3 to 1,300 kg/m3 or 1000 kg/m3 to 1,500 kg/m3 |
| Density accuracy | ± 2 kg/m3 |
| Nominal diameter | 1/2” to 3” |
| Ambient temperature | - 40 °C to +55 °C |
| Process temperature | - 40 °C to +130 °C |
| Process pressure absolute | According to flange specification |
| Process connection | ASME B16.5 Class 150 Tri-clamp ISO 2852 |
| Wetted parts | Titanium alloy |
| Approvals for potentially explosive atmospheres | ATEX, IECEx, CSA (C-US), NEPSI (CCC) |
| Outputs | 2x analog, 2x pulse (frequency), 1x status output |
| Inputs | 1x status input |
| Digital communication | Bell 202, Modbus RTU (RS-485), Profibus PA, Fieldbus |
| Transmitter version | Integrated, separately mounted, mounted in control cabinet |
| Certifications | EHEDG |
*Accuracy valid at reference conditions. ZS = Zero stability error = (Zero stability)/(Flowrate at the moment) x100%